images

Electrical panels for various segments like commercial building , apartments , individual houses and factories are designed as per customer's specification and manufactured to Indian standards. The Panels are performing in the industries for more than a year with full Customer's satisfaction.

images

It is state of art design to balance load condition and reduce line losses by using our APFC System which comprises of PLC Unit, Power Multimeter, Capacitor, Contactor etc. It is three phase sensing system and works on kvar regulation for better controlling of pf .

images

It is state of art design to balance load condition and reduce line losses by using our APFC System which comprises of Power Factor Controller, Capacitor, Contactor etc. It is single phase sensing system and works on target pf.

images

It is state of art design to reduce KVA demand, reduce line losses and improve voltage regulation in diesel generator by using our PLC Based APFC System. It helps in efficient loading , optimum capacity utilization and reduction in peak current demand by improving power factor in diesel generator which ranges from 100 KVA to 1500 KVA.

images

Clients can avail from us a trusted range of Auto Mains Failure Panels (AMF Panels). These are used for automatic changing over from the mains electricity supply to genset in case of the electricity fails. This system automatically changes the supply back to the mains and stops the genset whenever the mains supply is restored

images

Detuned reactors are specific three phase inductors dedicated to attenuating the amplification of harmonics on highly polluted networks and to protecting the different components of the installation. They form a complete product range from 6 to 100 kvar and are available in the most common tunings like 135, 190 and 215 Hz for network voltage of 400/415V 50Hz.

images

Active Harmonic Filters are based on Static Compensator (StatCom) philosophy which uses an IGBT based inverter to generate compensating current of any shape or size. Active Power Filters can do a lot more than just harmonic mitigation. APF solutions are used for harmonic mitigation, reactive power compensation, load balancing, and neutral correction. They can provide compensation on grid supply and are also fully compatible with DG operation.

images

We offers the widest range of LED products available. LED lighting provides incredible energy efficiency without sacrificing light quality and power output LED lighting is highly efficient, long lasting and environmentally friendly. We are dealing with street lights high bay lights and flood lights for industries.

images

Servo Voltage Stabilizers is a 3-phase, distortion-free, automatic voltage controller that gives perfectly stable output even under severe conditions of unbalanced voltage. It increases life of your equipment, reduced heating and minimal losses. You can now enhance the quality of power, as well as save power, by using servo voltage regulator/stabilser. It is a distortion less, servo controlled stabilizer available up to 350 KVA capacity.

images

India Has abundant sun power and with the increase need for energy and rising price of oil & gas. Solar is the purest form of energy which should be utilized . In order to achieve our goal for clean and affordable power , we provide fully integrated solution for successful implementation of on grid and off grid solar pv projects for our customers.

images

In Industries, commercial establishments, manufacturing plants etc. where the electrical system is huge and complex, it requires centralised monitoring of power, energy and control. ENERGY MONITORING SYSTEM is having such a facility and deals with "Demand side Management". The Energy Monitoring System helps an organization to achieve energy efficiency through well laid out procedures and methods and in over all cost savings. This savings vary from savings in energy bills, maximum demand charges, controlling energy wastages, better utilization of man power and avoidance of critical break down in the electrical systems etc.

images

In any industry, the electrical motor accounts for 55% to 60% of the electrical energy consumption Induction motors operate efficiently as long as they are loaded up from 60% to 85% loading. When these motors are operated below 50% loading, the Efficiency and Power Factor is very low. During lightly loaded condition (less than 50% loading), it is preferable to run motors in Star mode instead of Delta mode and this reduces your Electrical Bill

images

While power cuts eat into your profits, an inefficient DG set will simply add to your losses. Powered by Powerol engines, Mahindra Powerol DG sets have been designed to ensure you an efficient power supply. This also assures you years of hassle-free operations.lts Recovery Time, Easily The Best In Its Category, Guarantees A Seamless Switchover To The Back-Up Power. Moreover, Its Effective Governing System Controls The Voltage Fluctuations, Thus Ensuring Complete Safety Of Your Equipment.